Structural analysis, design and drawings from one model.
Model, analyze and design concrete, steel, cold-formed steel, wood, aluminum and glass structures to ACI 318‑19 and 318‑25, AISC 360‑22, AISI S100‑24, NDS 2024, SDPWS 2021, ADM 2020, ASCE 7 and NSCP 2015, and to Eurocodes 2 and 3, BS 8110, IS 456 and IS 800, then issue calculation reports and drawings.
Verification and transparency
Workflow
Model, load, analyze, design, detail and report in one model file.
1 Model
Grids, stories, frames, floors, walls and solids, drawn in plan, elevation or 3D, with a section designer, curved and tapered members, typical-story editing, automatic connectivity and a model check that names every problem. Import plans and 3D models from DXF. Parametric generators build editable buildings, wood-frame houses and ADUs, warehouses, car parks, canopies, towers, bridges, roofs and shells, stairs, decks and railings, with code-based floor loads. Every numeric field accepts feet-inch entries and arithmetic. Or describe the structure to the AI Assistant, with photos, drawings or video, and it builds the model with the program's own commands, every step one undo.


2 Load
Automatic seismic and wind loads to ASCE 7-16, ASCE 7-22 and NSCP 2015, with site seismic parameters by location, live load reduction and components and cladding. Code spectra and recorded ground motions from a built-in library. Strength, service and overstrength combinations to ASCE 7 or NSCP 203.3, each naming its source.


3 Analyze
Linear static, P-Delta, nonlinear static, modal, response spectrum, buckling and time history analysis of frames and shells, with rigid or flexible diaphragms, tension-only bracing and the AISC direct analysis method. Solid elements in the static, P-Delta and buckling cases. Equilibrium is checked on every run. Deformed shapes, force diagrams and contours in every view, and an earthquake animation you can record to video. The Windows desktop app adds a native solver for large models.


4 Design
Automatic design of reinforced concrete beams, columns, walls and floors, steel, composite and cold-formed steel members, joists and deck, wood members and light wood-frame buildings, aluminum members, glass, foundations and connections. Floors are designed in one click, thickness included. Members are coloured by ratio; every check opens with its clause.


5 Detail and draw
Reinforcement detailed in 3D with bar bending schedules and IFC 4 export. Coordinated drawing sets (foundation, framing and floor plans, elevations, sections, reinforcement drawings, schedules, notes and typical details) with review, approval and revisions, exported to PDF and DXF.

6 Report
Calculation reports in PDF, DOCX, XLSX, CSV and HTML, built from templates: loads with their derivations, analysis summaries and every design check written as a vertical calculation. Issued revisions stay with the project. Compliance is affirmed only when every check passes.


Design codes and status
Status: Verified benchmarked or tested and recorded in the validation record; With limits released with stated exclusions; Tested released with automated tests, not yet in the validation record; Not offered.
Concrete
| Capability | Code and edition | Status |
|---|---|---|
| Beams and columns: automatic design, three-station beam reinforcement, slenderness, Chapter 18 seismic frames and joints | ACI 318-19, ACI CODE-318-25, NSCP 2015 | Verified |
| Walls: bearing and shear walls, special structural walls with boundary elements, wall piers, coupling beams, retaining and basement walls, elevator cores | ACI 318-19, ACI CODE-318-25, NSCP 2015 | Verified |
| Floors: one-click design of one-way, two-way, flat plate, flat slab and cantilever floors, punching shear, deflections, thickness optimisation, floor reinforcement drawings | ACI 318-19, ACI CODE-318-25, NSCP 2015 | Tested |
| Concrete design to the 2025 edition, selectable per model: members, floors, foundations, anchoring; every changed provision mapped, exclusions listed | ACI CODE-318-25 | With limits |
| Hollow core slabs, with continuity and cantilevers | ACI 318-19 or ACI CODE-318-25 | Verified |
| Prestressed members other than hollow core | None | Not offered |
| Beams and columns of rectangular section | EN 1992-1-1:2004; BS 8110-1:1997; IS 456:2000 | With limits |
Steel
| Capability | Code and edition | Status |
|---|---|---|
| Members (I-shapes, channels, tees, angles, HSS, box, pipe, bars, built-up and non-prismatic) with the direct analysis method and automatic section selection | AISC 360-22 LRFD | Verified |
| Open web steel joists (K and LH verified; DLH, KCS and joist girders with limits) | SJI 100-2025 | With limits |
| Composite beams, composite columns and metal deck floors | AISC 360-22; ANSI/SDI C-2017 | Verified |
| Members, Class 4 sections and shear buckling | EN 1993-1-1:2005 and EN 1993-1-5; IS 800:2007 | With limits |
Wood
| Capability | Code and edition | Status |
|---|---|---|
| Sawn lumber, timbers and glulam members | NDS 2024 LRFD | Verified |
| Structural composite lumber and I-joists from the listed evaluation reports | NDS 2024 Ch. 7 and 8 | Verified |
| Light wood-frame buildings: framed walls, floors and roofs, segmented and perforated shear walls, diaphragms, collectors, hold-downs and connector hardware, drift, automatic design and framing drawings | SDPWS 2021; ASCE 7 | Verified |
| Wood connections: bolts, lag and wood screws, nails, split rings, shear plates, timber rivets, catalog hangers and post bases; batch design and reuse at similar nodes | NDS 2024 Ch. 11 to 14 and Appendix E | Verified |
Cold-formed steel
| Capability | Code and edition | Status |
|---|---|---|
| C-sections and tracks (SSMA designations) | AISI S100-24 LRFD | Verified |
| Z, angle and hat sections by the Direct Strength Method; purlins with through-fastened or standing seam roofs; purlin anchorage | AISI S100-24 LRFD | With limits |
Foundations
| Capability | Code and edition | Status |
|---|---|---|
| Isolated, combined, strap and wall footings, mats and pile caps from the support reactions, with pedestals and automatic sizing | ACI 318-19, ACI CODE-318-25 or NSCP 2015 | Verified |
| Lateral pile analysis by linear subgrade reaction | ACI 318-19, ACI CODE-318-25 or NSCP 2015 concrete; AISC 360-22 steel | Verified |
| Lateral pile analysis by p-y curves (soft clay, stiff clay, sand); grade beams and foundation ties | Same | With limits |
Connections
| Capability | Code and edition | Status |
|---|---|---|
| Steel joints: shear, moment, brace, splice and base templates sized to the analysis forces, checked by the component method and by finite elements; batch design and reuse at similar joints | AISC 360-22 | Verified |
| Slip-critical bolts, fatigue, HSS T, Y and cross connections, seismic load sets, fillers, uniform force method | AISC 360-22; AISC 341-22 | With limits |
| Column base plates: cast-in anchors, anchor reinforcement, shear lugs and the 17.10 seismic options | AISC 360-22; ACI 318-19, ACI CODE-318-25 Ch. 17 or NSCP Section 417 | Verified |
| Post-installed and adhesive anchors | Same | With limits |
Loads
| Capability | Code and edition | Status |
|---|---|---|
| Seismic: equivalent lateral force, accidental torsion, drift, redundancy, irregularities, spectrum scaling | ASCE 7-16; ASCE 7-22 | Verified |
| Seismic static force procedure and wind | NSCP 2015 Sections 207 and 208 | Verified |
| Wind (directional, envelope, components and cladding); live load reduction | ASCE 7-16; ASCE 7-22 | Verified |
| Combinations, snow, wind and seismic actions | EN 1990; EN 1991-1-3; EN 1991-1-4; EN 1998-1 | With limits |
| Wind, seismic and combinations | IS 875 (Part 3), IS 1893 (Part 1):2016; BS 6399-2; 1997 UBC; Dubai Building Code 2021 | With limits |
Aluminum, glass and special structures
| Capability | Code and edition | Status |
|---|---|---|
| Aluminum members: I-shapes, channels and rectangular tubes, tempers T5 to T9, unwelded; some interaction and torsion items reported for review | ADM 2020 LRFD | With limits |
| Glass: stress, deflection and laminated effective thickness checks from entered values | Program criteria, not attributed to a standard | For review |
| Shipping container structures: simplified and detailed procedures, stacked and adjoining units | IBC 2021 3115.8 | Verified |
| Railings and decks: guard loads applied, members designed by their material code | IBC 2021 1607.9 | Verified |
| Welded aluminum and round aluminum tubes | None | Not offered |
Every row has a provision register in the program listing the clauses used and those not checked. Full code and edition table
Calculation reports
Each design check is written as a vertical calculation: the clause and edition, the equation, the values substituted and the result. Checks the program does not perform are listed as not checked, so the member shows as incomplete or for review instead of passing.
See the sample report
Analysis benchmarks
A sample of the recorded benchmarks. Tolerances were fixed before assessment.
| Case | Reference | Tolerance | Result |
|---|---|---|---|
| Simply supported beam, uniform load | Closed form, 5wL⁴/384EI and wL²/8 | 1e-9 | Pass |
| Spatial frame, 37 nodes, 67 members, 3 stories | Independent solver | 1e-6 | Largest difference 3.6e-13 |
| 3-story shear building, all 9 modes | Closed-form frequencies | 1e-8 | Pass |
| Clamped square plate, uniform pressure, 16 × 16 mesh | Timoshenko and Woinowsky-Krieger | 1 % | Ratio 1.0033 |
| Scordelis-Lo roof, 16 × 16 facets | Published reference 0.3024 ft | 5 % | 100.3 % |
Sample projects
Each sample was generated, analyzed and designed in the program as shown. The pictures follow the theme of this page. What is different in every one of them: the model, the loads, the analysis, the design, the connections, the foundations, the drawings and the report are in one model file, every check names its clause, and a check the program does not perform is reported as not checked instead of passing.
Concrete frame
Six-story special moment frame, ACI 318-19. Generated by the Midrise building generator with one floor slab per bay, loaded to ASCE 7-22, and designed and detailed automatically: 306 beams and columns, all passing.
- The seismic checks of Chapter 18 (strong column and weak beam, joint shear, hoops, probable shear) run with the strength checks. In this sample the beam-column joints, not the axial and bending interaction, set the column size.
- Reinforcement is selected, detailed in 3D and scheduled; framing plans, elevations and the calculation report come from the same model.
Steel frame
Four-story braced frame, AISC 360-22 LRFD. 236 members with seismic and wind loads to ASCE 7-22 and floors acting as membranes, so the beams carry the floor loads.
- Automatic section selection picked the lightest adequate library shape for each group against a target ratio of 0.85, repeating the analysis with the selected shapes: W14X68 columns, W8X31 beams, HSS9X9X3/16 braces.
- All 236 members pass; the governing ratios run from 0.38 to 0.84.


Steel connections
Beam-to-column joint of the steel sample, designed in one command. The program proposed nine configurations, ranked them, and placed the recommended one in the designer: an extended end plate to the column flange and a welded beam with a bottom haunch to the column web.
- The joint is designed with every member at the node, from the member forces of the analysis, in the same file as the frame.
- Component checks and a finite-element model of the plates, bolts and welds are both run: here 109 checks pass, the governing one at 1.00 against the automatic design target of 0.90, and the program says so.


Wood frame
Light wood-frame ADU, NDS 2024 and SDPWS 2021. Built from wall, ceiling and roof assemblies with door and window openings, with seismic and wind loads to ASCE 7-22.
- One model gives the shear lines, story drift, hold-downs, diaphragms, collectors and framing drawings; in this sample the four shear lines are at 0.17 to 0.20 of their capacity (ASD).
- An automatic least-material design proposes studs, sheathing, nailing, joists and rafters, and names what it could not resolve.


Foundations
Isolated footings of the concrete sample, ACI 318-19. All 20 footings were sized in one step from the support reactions, to a target ratio of 0.95.
- Footing FD5 under column M5: 4000 by 4000 by 500 mm, 23 checks, soil bearing at 0.94 and one-way shear at 0.95.
- The soil profile here uses presumptive values, so the program labels the result preliminary and lists settlement as not checked. It does not report a pass.


Parametric modelling
Complete structures from a few parameters. Choose a template, set its dimensions and options, and watch the preview follow. The structure is created with its sections, supports, stories, grids and code-based floor loads.
- A generated structure stays parametric: open it again, change a value, and the model is rebuilt.
- The same generators cover buildings, wood-frame houses, warehouses, roofs, shells, bridges, towers, stairs and foundations.
Structural drawings
Framing plans and elevations, PDF and DXF.
Download the drawings (PDF, 160 sheets, 12.3 MB)
Download the DXF files (zip, 38.6 MB)
Sample model
.rs2 file that opens in the program.
Download the model (.rs2, 0.5 MB), then open it with the free trial.
More pictures of projects and outputs are in the Gallery.
Pricing
Three plans by level of work, monthly or annual. Every account starts with a free 30-day trial with every feature. Filipino engineers practising locally get 40% off for projects in the Philippines; the first 100 seats get 30% off their first year. Pricing and discounts
Standard
Complete design of ordinary buildings in concrete, steel and wood, with ASCE 7 and NSCP 2015 loads, footings and reports.
Professional
Complex buildings: time history and buckling, mats and piles, connections, drawings and the Windows desktop app.
Advanced Early access
Nonlinear seismic design, existing buildings to ASCE 41-23, and coupled soil-structure interaction with a 3D soil domain.
Support
A complete in-app manual of about 160 searchable pages, also published here, provision registers for every design module, an in-app Feedback and Requests workspace where you can vote on and follow requests, and e-mail support at rapidstructure@jmvccse.com.
Frequently asked questions
Which codes and editions are supported?
ACI 318-19 and ACI CODE-318-25, AISC 360-22, AISI S100-24, SJI 100-2025, ANSI/SDI C-2017, NDS 2024, SDPWS 2021, ADM 2020, ASCE 7-16, ASCE 7-22, IBC 2021 and NSCP 2015, and for international work EN 1990, 1991, 1992-1-1, 1993-1-1 and 1998-1, BS 8110-1, IS 456, IS 800, IS 875, IS 1893, the 1997 UBC and the Dubai Building Code 2021, among others, plus glass checks to program criteria. The codes page lists each one with its status.
What does it not check?
Every design module ends its provision register with a list of what is not checked, and the program's limitations page lists the open items. A check that is not performed is reported as not checked or excluded, with the reason, and is never shown as passing.
Which devices, and does it work offline?
It runs in current browsers on computers, tablets (including iPad) and phones, and as a Windows desktop app, which adds a native solver for large models. Installed as an app, from the browser or as the desktop program, it opens offline for up to 7 days after the last sign-in check; the site seismic lookup needs a connection. The desktop installer is not yet code-signed, so Windows shows an unrecognized app warning on the first run.
Who is responsible for the design?
You are. The program implements the provisions listed in its registers as stated; it does not judge whether the model, loads, combinations or code selections suit a project. A report affirms compliance only when every check passes.
Is a perpetual licence available?
No. RapidStructure is offered by subscription only. The program is in active development, with updates released at least twice a week that add features, functions, design codes and code editions, and corrections. A perpetual licence would fix a seat at one version and leave it without those additions and fixes. Every subscription includes all updates released while it is active, at no extra cost. If you prefer to pay once a year, annual billing is priced at 10 months.
Where is my model data stored?
On your own device. Models are kept in your browser while you work and in the .rs2 files you save; they are not uploaded to our servers unless you attach one to a feedback report. Anything you send to the AI Assistant goes directly from your device to your AI provider. Our servers hold your account and role, your licence acceptance, your session and activity records (last activity, platform and program version) and any feedback you send, with its notification settings. Save your models as files and back them up, because clearing the browser's data removes its working copy.
Early access
This is an early access release. RapidStructure is in active development, so expect updates at least twice a week: new features, design codes and editions, and corrections. The web app updates itself, the desktop program offers each update, and Help lists what changed in every version.
The first 30 days are free, with every feature and no card; reports and drawings of your models are checked on screen during the trial. In return we ask one thing: tell us what you find. Problems, missing codes, results you question and features you need all go through Feedback & Requests inside the program, where you can follow each one to its release.
Send feedback in three steps
- In the program, open Help, then Feedback & Requests.
- Pick the category (problem, feature, improvement, design code, calculation concern or other), fill in its short form and attach screenshots if they help.
- Select Review, then Submit. You get a tracking number and a notice at every change of status.
Start your free trial
Sign in with a Google account and the trial starts at once. 30 days with every feature, no card. Filipino engineers practising locally get 40% off for projects in the Philippines; verified students and teachers use it free.
Start free trial